Publications by Year
-
Design and Performance of an Atmospheric Pressure Ion Mobility Fourier Transform Ion Cyclotron Resonance Mass Spectrometer Xiaoting Tang, James E. Bruce, Herbert H. Hill, Jr., Rapid Communications in Mass Spectrometry, 2007 21, 1115-1122.
-
A Small Subsurface Ion Mobility Spectrometer Sensor for Detecting Environmental Soil-Gas Contaminants Abu B. Kanu, Herbert H. Hill, Jr., Molly M. Gribb and Robert N. Walters, Journal of Environmental Monitoring, 2007, 9, 51-60.
-
Gas Phase Chiral Separations by Ion Mobility Spectrometry, Prabha Dwivedi, Ching Wu, Laura M. Matz, Brian H. Clowers, William F. Siems, Herbert H. Hill, Jr., Analytical Chemistry, 2006, 78, 8200-8206.
-
Characterizing Electrospray Ionization Using Atmospheric Pressure Ion Mobility Spectrometry, Xiaoting Tang, James E. Bruce, Herbert H. Hill, Jr., Analytical Chemistry, 2006, 78, 7751-7760.
-
Reduction in False Positive Responses for Explosives Detection Using Ion Mobility Mass Spectrometry (IMMS), Herbert H. Hill, Jr., Prabha Dwivedi, and Abu B. Kanu, Bulletin of Laser and Spectroscopy Society of India, 2006, 14, 92-103.
-
Detection of Aqueous Phase Chemical Warfare Agent Degradation Products by Negative Mode Ion Mobility Time-of-Flight Mass Spectrometry [IM(tof)MS], Wes. E. Steiner, Charles S. Harden, Feng Hong, Steve J. Klopsch, Herbert H. Hill, Jr., and Vincent M. McHugh, Journal of the American Society for Mass Spectrometry, 2006, 17, 241-245.
-
Ion-Neutral Potential Models in Atmospheric Pressure Ion Mobility time-of-flight mass spectrometry IM(tof)MS, Wes E. Steiner, William A. English, Herbert H. Hill, Jr. J. Physical Chemistry A, 110(5), 2006, 1836-1844.
-
An In-Situ Ion Mobility Spectrometer Sensor System for Detecting Gaseous VOCs in the Vadose Zone, Dick Sevier; Molly Gribb; Robert Walters; Jerome Imonigie; Kevin Ryan; Abu Kanu; Herbert Hill; Feng Hong; Jake Baker; and Sin Ming Loo;, Geotechnical Special Publication (Unsaturated Soils 2006), 1(147), 225-234, 2006.
-
Influence of cation adduction on the separation characteristics of flavonoid diglycoside isomers using dual gate-ion mobility-quadrupole ion trap mass spectrometry. Clowers, Brian H.; Hill, Herbert H., Jr. Journal of Mass Spectrometry, 2006, 41(3), 339-351.
-
Hadamard Transform Ion Mobility Spectrometry. Clowers, Brian H.; Siems, William F.; Hill, Herbert H.; Massick, Steven M. Analytical Chemistry 2006, 78, 44-51.
-
Ion Mobility Spectrometry for Monitoring the Destruction of Chemistry Warfare Agents, Herbert H. Hill and Wes. E. Steiner, in Ecological Risks Associated with the Destruction of Chemical Weapons, pages 157-166, V. M. Kolodkin and W. Ruck (eds.) Springer, 2006.
-
Separation Efficiency of a Chemical Warfare Agent Simulant in an Atmospheric Pressure Ion Mobility Time-of-Flight Mass Spectrometer, Wes E. Steiner, William A. English, and Herbert H. Hill, Analytica Chimica Acta, January 2005.532(1), 37-45
-
Separation of Sodiated Isobaric Disaccharides Using Electrospray Ionization-Atmospheric Pressure Ion Mobility-Time of Flight Mass Spectrometry Brian H. Clowers, Brad Bendiak, Prahba Dwivedi, Wes E. Steiner, Herbert H. Hill Jr., Journal of the American Society for Mass Spectrometry (JASMS), 2005, 16(5) 660-669 (Featured Article on Cover of Journal).
-
Mass Analysis of Mobility-Selected Ion Populations Using Dual Gate, Ion Mobility, Quadrupole Ion Trap Mass Spectrometry, Brian H. Clowers and Herbert H. Hill, Jr., Analytical Chemistry, 2005, 77, 5877-5882.
-
Modification of Whey Protein Concentrate Hydrophobicity by High Hydrostatic Pressure, Xiaoming Liu, Joseph R. Powers, Barry G. Swanson, Herbert H. Hill and Stephanie Clark, Innovative Food Science & Technologies (IFSET), 2005, 6, 310-317.
-
Surface Detection of Chemical Warfare Agent Simulants and Degradation Products, Abu B. Kanu, Paul E. Haigh and Herbert H. Hill, Analytica Chimica Acta, 553, 148-159, 2005.
-
Detection of a Chemical Warfare Agent Simulant in Various Aerosol Matrices by Ion Mobility Time of Flight Mass Spectrometry, Wes E. Steiner, Steve J. Klopsch, William A. English, and Herbert H. Hill, Analytical Chemistry 2005, 77, 4792-4799
-
High Hydrostatic Pressure Affects Flavor-binding properties of Whey protein Concentrate, X. Liu, J. R. Powers, B. G. Swanson, H. H. Hill and S. Clark, J. Food Science 2005, 70(9), C581-C585
-
Ion Mobility Spectrometry Method and Apparatus, H. H. Hill and M. Tam, U. S. Patent, No. 7,071,465, July 4, 2006.
-
Atmospheric pressure Matrix-Assisted Laser Desorption/Ionization with Analysis by Ion Mobility Time-of-Flight Mass Spectrometry, Wes E. Steiner, Brian H. Clowers, William A. English, and Herbert H. Hill, Jr., Rapid Communications in Mass Spectrometry, 18(8):882-888, 2004.
-
Ion Mobility Mass Spectrometry for Monitoring the Destruction of Chemical Warfare Agents, Herbert H. Hill and Wes. E. Steiner, NATO-Russia Advanced Research: Ecological Risk Associated with the Destruction of Chemical Weapons, 2004, 157-166. (Invited)
-
Differentiation of Intracellular Peptidases of Starter and Adjunct Cultures Using Matrix-Assisted-Laser-Desorption/Ionization Time-of-Flight Mass Spectrometry, Elly Soeryapranata, Joseph R. Powers, Karen M. Weller, Herbert H. Hill, Jr., William F. Siems, Swiss Society of Food Science and Technology, 37(1) 17-22, 2004.
-
Secondary Electrospray Ionization-Ion Mobility Spectrometry (SESI-IMS) for Explosive Vapor Detection, Maggie Tam and Herbert H. Hill, Jr., Analytical Chemistry, 2004, 76 2741-2747.
-
Liquid Phase Ion Mobility Spectrometry, Herbert H. Hill and Maggie Tam, Provisional Patent, WSU 2004.
-
Electrospray Ionization-Ion Mobility Spectrometry: A Rapid Analytical Method for Aqueous Nitrate and Nitrite Analysis, Prabha Dwivedi, Laura M. Matz, David A. Atkinson, and Herbert H. Hill, Jr., Analyst, 129, 139-144, 2004.
-
(Invited) Ion Mobility Spectrometry: Recent Developments and Novel Applications, Abu B. Kanu, and Herbert H. Hill, LabPlus International, April/May 2004.
-
Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry of Lipids: Ionization and Prompt Fragmentation Patterns, Khalid A. Al-Saad, Vladimir Zabrouskov, William F. Siems, N. Richard Knowles, Richard M. Hannan and Herbert H. Hill, Jr., Rapid Commun. In Mass Spectrometry, 17, 87-96, 2003.
-
Rapid Separation of Phenylthiohydantoin Amino Acids: Ambient Pressure Ion Mobility Mass Spectrometry (IMMS), Wes E. Steiner, Brian H. Clowers, and Herbert H. Hill, Jr., Analytical and Bioanalytical Chemistry, 375, 99-102, 2003.
-
Structural Analysis of Phosphatidylcholines by Post-source Decay Matrix-assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry, Khalid A. Al-Saad, Vladimir Zabrouskov, William F. Siems, N. Richard Knowles, and Herbert H. Hill, Jr., JASMS, 2003.
-
Secondary Ionization of Chemical Warfare Agent Simulants: Atmospheric Pressure Ion Mobility Time-of-Flight Mass Spectrometry, Wes. E. Steiner, Brian H. Clowers, Paul E. Haigh, and Herbert H. Hill, Analytical Chemistry, 2003, 75, 6068-6076.
-
Evaluation of Sulfonylurea Herbicides Using High Resoluiton Electrospray Ionization Ion Mobility Quadrupole Mass Spectrometry, B. H. Clowers, W. E. Steiner, H. M. Dion, L. M. Matz, M. Tam, E. E. Tarver and H. H. Hill, Field Anal. Chem. Technol., 5(6), 2002, 302-312.
-
Investigation of Drift Gas Selectivity in High Resolution Ion Mobility Spectrometry with Mass Spectrometry Detection, Laura M. Matz and Herbert H. Hill, Jr., Luther W. Beegle and Isik Kanik, Jour. Am. Soc. Mass Spectrom., 13, 300-307, 2002.
-
Construction and Characterization of a High-Flow, High-Resolution Ion Mobility Spectrometer for Detection of Explosives After Personnel Portal Sampling, Ching Wu, Wes E. Steiner, Pete S. Tornatore, Laura M. Matz, William F. Siems, David A. Atkinson, Herbert H. Hill, Jr., Talanta, 57(1), 123-134, 2002.
-
Evaluation of Capillary Liquid Chromatography-Electrospray Ionization Ion Mobility Spectrometry with Mass Spectrometry Detection, Laura M. Matz, Heather M. Dion, Herbert H. Hill, Jr., J. Chromatogr., 946, 59-68, 2002.
-
Evaluation of Micro-Electrospray Ionization with Ion Mobility Spectrometry/Mass Spectrometry, Laura M. Matz, Wes E. Steiner, Brian H. Clowers, Herbert H. Hill, International Jour. Mass Spectrometry, 213, 191-202, 2002* (Also featured in Proteomics Select, 2002, Issue 1).
-
Evaluating the Separation of Amphetamines by Electrospray Ionization/Ion Mobility Spectrometry/MS and Charge Competition within the ESI Process, Laura M. Matz, and Herb H. Hill, Analytical Chemistry, 2002, 74, 420-427.
-
Effects of Drift-Gas Polarizability on Glycine Peptides in Ion Mobility Spectrometry, Luther W. Beegle, Isik Kanik, Laura M. Matz, Herbert H. Hill, Jr., International Jour. Of Mass Spectrometry, 216, 257-268, 2002.
-
Charge Location on Gas Phase Peptides, Herbert H. Hill, Jr., Chandler H. Hill, G. Reid Asbury, Ching Wu, Laura M. Matz, Toshiko Ichiye, International Jour. Of Mass Spectrometry, 219, 23-37, 2002.
-
Two-Dimensional Separations with Electrospray Ionization Ambient Pressure High-Resolution Ion Mobility Spectrometry/ Quadrupole Mass Spectrometry, Laura M. Matz, G. Reid Asbury and Herbert H. Hill, Jr., Rapid Commun. Mass Spectrometry, 16, 670-675, 2002.
-
Separation of Benzodiazepines by Electrospray Ionization Ion Mobility Spectrometry-Mass Spectrometry, Laura M. Matz, Herbert H. Hill, Jr., Analytica Chemica Acta, 457, 235-245, 2002.
-
Detection of Inorganic Ions From Water by Electrospray Ionization-Ion Mobility Spectrometry, Heather M. Dion, Luke K. Ackerman, Herbert H. Hill, Jr., Talanta, 57, 1161-1171, 2002.
-
Rapid Screening of Aqueous Chemical Warfare Agent Degradation Products: Ambient Pressure Ion Mobility Mass Spectrometry, W. E. Steiner, B. H. Clowers, L. M. Matz, W. F. Siems, and H. H. Hill, Jr., Analytical Chemistry, 2002, 74, 4343-4352 * (Also featured in Medline, 2002, PMID: 12236341).
-
Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry Method for the Quantification of β-Casein Fragment (f193-209), E. Soeryapranata, J. R. Powers, H. H. Hill, Jr., W. F. Siems, III, K. Al-Saad, and K. M. Weller, J. Food Sci., 67, 2002, 534-538.
-
Relationship Between MALDI-TOF Analysis of β-CN f193-209 Concentration and Sensory Evaluation of Bitterness Intensity of Aged Cheddar Cheese, E. Soeryapranata, J. R. Powers, F. Fajarrini, K. M. Weller, H. H. Hill, Jr., and W. F. Siems, III., J. Agric. Food Chem., 50(17), 2002, 4900-4905.
-
Conventional Analytical Methods for Chemical Warfare Agents, H. H. Hill and S. J. Martin, Pure Appl. Chem. , 74(12), 2281-2291, 2002.
-
Analysis of Plant Phosphatidylcholines by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry, Vladimir Zabrouskov, Khalid A. Al-Saad, William F. Siems, Herbert H. Hill, Jr. and N. Richard Knowles, Rapid Commun. In Mass Spectrometry, 15, 935-940, 2001.
-
Evaluation of Opiate Separation by High-Resolution Electrospray Ionization-Ion Mobility Spectrometry/Mass Spectrometry, Laura M. Matz and Herb H. Hill, Jr., Analytical Chemistry, 2001, 73, 1664-1669.
-
Evaluation of Suspected Interferents for TNT Detection by Ion Mobility Spectrometry, Laura M. Matz, Pete S. Tornatore, Herb H. Hill, Jr., Talanta, 54, 171-179, 2001.
-
Competitive Sorption between Glyphosate and Inorganic Phosphate on Clay Minerals and Low Organic Matter Soils, Heather M. Dion, Jim B. Harsh, Herb H. Hill, Jour. of Radioanalytical and Nuclear Chem., 249, 385-390, 2001.
-
Electrospray Ionization with Ambient Pressure Ion Mobility Separation and Mass Analysis by Orthogonal Time of flight Mass Spectrometry, Wes E. Steiner, Brian H. Clowers, Katrin H. Fuhrer, Marc Gonin, Laura M. Matz, William F. Siems, Albert J. Schultz, and Herb H. Hill, Rapid Commun. in Mass Spectrometry, 15, 2221-2226, 2001* (also featured in Medline 2002 PMID 11746889 and Spectroscopy Now, November 20, 2001)
-
Electrospray Ionization High-Resolution Ion Mobility Spectrometry for the Detection of Organic Compounds, 1. Amino Acids, Luther W. Beegle, Isik Kanik, Laura M. Matz, Herb H. Hill, Analytical Chemistry, 2001, 73, 3028-3034.
-
Initial Study of Electrospray Ionization – Ion Mobility Spectrometry for the Detection of Metal Cations, H. M. Dion, L. K. Ackerman and H. H. Hill, Int. J. Ion Mobility Spectrometry, 4, 2001, 31-33.
-
Analysis of Explosives Using Electrospray Ionization / Ion Mobility Spectrometry (ESI/IMS), G. R. Asbury, J. Klasmeier, and H. H. Hill, Jr., Talanta, 50(6), 1291-1298, 2000.
-
Reverse polarity capillary zone electrophoretic determination of ethylenediamine-tetraacetic acid and N-hydroxyethylethylenediaminetriacetic acid in Hanford defense waste, A. A. Okemgbo, H. H. Hill, Jr., S. G. Metcalf, and M. A. Bachelor, Journal of Microcolumn Separations, 12(1), 48-56, 2000.
-
Separation of Isomeric Peptides Using Electrospray Ionization / High Resolution Ion Mobility Spectrometry, C. Wu, W. F. Siems, and H. H. Hill, Jr., Anal. Chem., 2000, 72, 391-395.
-
Secondary Electrospray Ionization Ion Mobility Spectrometry - Mass Spectrometry of Illicit Drugs, C. Wu, W. F. Siems, and H. H. Hill, Jr., Anal. Chem., 2000, 72, 396-403.
-
Using Different Drift Gases to Alter Separation Factors (a) in Ion Mobility Spectrometry, G. R. Asbury and H. H. Hill, Jr., Anal. Chem., 2000, 72, 580-584.
-
Evaluation of High Resolution Ion Mobility Spectrometry as an Analytical Separation Device in Chromatographic Terms, G. R. Asbury and H. H. Hill, Jr., J. Microcolumn Separations, 12(3), 172-178, 2000.
-
Separation of Amino Acids by Ion Mobility Spectrometry, G. R. Asbury and H. H. Hill, Jr., Journal of Chromatography A, 2000.
-
Liquid Sheath Flow Electrospray Ionization Feasibility Study of Direct Water Analysis with the Use of High-Resolution Ion-Mobility Spectrometry, Laura M. Matz, Brian H. Clowers, Wes E. Steiner, William F. Siems, and Herbert H. Hill, Jr., Field Anal. Chem. and Tech., 5, 91-96, 2001.
-
Gas Chromatography, G. A. Eiceman, H. H. Hill, Jr., and J. Gardea-Torresday, Analytical Chemistry, 2000, 72, 137-144.
-
Surface Ionization Ion Mobility Spectrometry, C. Wu, H. H. Hill, Jr., U. Kh. Rasulev, E. G. Nazarov, Anal. Chem., 1999, 71, 273-278.
-
Electrospray High Resolution Ion Mobility Spectrometry of Biological Molecules, C. Wu, W. F. Siems, Y.-H. Chen and H. H. Hill, Jr., in 7th International Workshop for Ion Mobility Spectrometry, C. S. Harden (ed.), International Society of Ion Mobility Spectrometry, Hilton Head, South Carolina, 1999.
-
Improved Supercritical Fluid Chromatography / Ion Mobility Spectrometry Interface, C. Wu, W. F. Siems, H. H. Hill, Jr., and R. M. Hannan, Journal of Microcolumn Separations, 11(4), 251-257, 1999.
-
Atmospheric Pressure Ion Mobility Spectrometry of Protonated and Sodiated Peptides, C. Wu, J. Klasmeier, and H. H. Hill, Jr., Rapid Comm. Mass Spec., 13(12), 1138-1142, 1999.
-
Determination of Nitrate and Nitrite in Hanford Defense Waste By Reverse Polarity Capillary Zone Electrophoresis, A. A. Okemgbo, H. H. Hill, Jr., S. G. Metcalf, and M. A. Bachelor, Journal of Chromatography A, 844, 387-394, 1999.
-
Reverse Polarity Capillary Zone Electrophoretic Analysis of Nitrate and Nitrite in Natural Water Samples, A. A. Okemgbo, W. F. Siems, H. H. Hill, Jr., and S. G. Metcalf, Anal. Chem., 1999, 71, 2725 -2731.
-
Metal Interferences in Reverse Polarity Capillary Zone Electrophoretic Analysis of Hanford Defense Waste for Ethylenediaminetetraacetic Acid (EDTA) and N-Hydroxyethylethylenediaminetriacetic Acid (HEDTA), A. A. Okemgbo, H. H. Hill, Jr., S. G. Metcalf, and M. A. Bachelor, Analytica Chimica Acta, 396(2-3), 105-116, 1999.
-
Analysis of Triglycerols and Whole Oils by Matrix-Assisted Laser Desorption/Ionization (MALDI) Time of Flight Mass Spectrometry, G. R. Asbury, K. Al-Saad, W. F. Siems, R. M. Hannan, H. H. Hill, Jr., Journal of the American Society for Mass Spectrometry, 10, 983-991, 1999.
-
Separation and Identification of Some Chemical Warfare Degradation Products Using Electrospray High Resolution Ion Mobility Spectrometry With Mass Selected Detection, G. R. Asbury, C. Wu, W. F. Siems, and H. H. Hill, Jr., Anal. Chimica Acta, 404(2), 273-283, 2000.
-
Negative Ion Electrospray Ion Mobility Spectrometry, G. R. Asbury and H. H. Hill, Jr., International Journal of Ion Mobility Spectrometry, 2, 1-8, 1999.
-
Book Review: Analytical Gas Chromatography (Second Edition), H. H. Hill, Jr., Journal of the American Chemical Society, 121(4), 894, 1999.
-
Electrospray Ionization Ion Mobility Spectrometry as A Field Monitoring Method for the Detection of Atrazine in Natural Water, C. Wu, A. P. Gamerdinger, and H. H. Hill, Jr., Field Analytical Chemistry and Technology, 2(3), 155-161, 1998.
-
Analytical Determination of Nicotine in Tobacco by Supercritical Fluid Chromatography / Ion Mobility Detector, C. Wu, W. F. Siems, H. H. Hill, Jr., and R. M. Hannan, Journal of Chromatography A, 811, 157-161, 1998.
-
Detection of Carbohydrates by Electrospray Ionization - Ion Mobility Spectrometry following Microbore High-Performance Liquid Chromatography, D-S. Lee, C. Wu, H. H. Hill, Jr., Journal of Chromatography A, 822, 1-9, 1998.
-
Electrospray Ionization High Resolution Ion Mobility Spectrometry, C. Wu, W. F. Siems, G. R. Asbury, H. H. Hill, Jr., Anal. Chem., 1998, 70, 4929-4938.
-
Supercritical Fluid Extraction of 2,4-D from Soils: pH and Organic Matter Effects, E. A. Rochette, J. B. Harsh, and H. H. Hill, Jr., Soil Science Society of America Journal, 62(3), 602, 1998.
-
Electrospray High Resolution Ion Mobility Spectrometry Mass Spectrometry, C. Wu and H. H. Hill, Jr. in 6th International Workshop for Ion Mobility Spectrometry, J. I. Baumbach and J. Stach (eds.), International Society of Ion Mobility Spectrometry, Dortmund, Germany, 1998, pp. 268-280.
-
Gas Chromatography, G. A. Eiceman, H. H. Hill, Jr., B. Davani, and J. Gardea-Torresday, Anal. Chem., 1998, 70, 321R-340R.
-
Capabilities and Limitations of Ion Mobility Spectrometry for Field Screening Applications, H. H. Hill, Jr. and G. Simpson, Field Anal. Chem. and Technol., 1(3), 119-134, 1997.
-
Surface Ionization - Ion Mobility Spectrometry”, H. H. Hill, Jr., C. Wu, U. K. Rasulev, and E. G. Nazarov in 5th International Workshop on Ion Mobility Spectrometry Proceedings, H. H. Hill, Jr. and D. A. Atkinson (eds.), Pullman, WA, 1997, pp. 353-372.
-
Fundamental Reviews of Field Analytical Chemistry, V. Lopez-Avila and H. H. Hill, Jr., Anal. Chem., 69, 289R-305R, 1997.
-
Soil Component Interaction with 2,4-Dichlorophenoxyacetic Acid Under Supercritical Fluid Conditions, E. A. Rochette, J. B. Harsh, and H. H. Hill, Jr., Environ. Sci. & Technol., 30(4), 1220-1226, 1996.
-
Thermal Effects on Electrospray Ionization Ion Mobility Spectrometry, Y. H. Chen, H. H. Hill Jr., and D. P. Wittmer, Int. J. Mass Spec. and Ion Processes, 154, 1-13, 1996.
-
Evaluation of Gas Chromatography Coupled with Ion Mobility Spectrometry for Monitoring Vinyl Chloride and Other Chlorinated and Aromatic Compounds in Air Samples, G. Simpson, M. Klasmeier, H. H. Hill, Jr., D. A. Atkinson, G. Radolovich, V. Lopez-Avila, T. L. Jones, J. High Res. Chromatogr., 19, 301-312, 1996.
-
Fourier Transform Electrospray Ion Mobility Spectrometry, Y. H. Chen, W. F. Siems, and H. H. Hill, Jr., Analytica Chimica Acta, 334, 75-84, 1996.
-
Fundamental Reviews of Gas Chromatography, G. A. Eiceman, H. H. Hill, Jr., B. Davani, and J. Gardea-Torresday, Anal. Chem., 68, 291R-308R, 1996.
-
Metal Selectivity by Ion Mobility Discrimination in a Flame Ionization Detector, M. M. Gallagher and H. H. Hill, Jr., in Selective Detectors, R. E. Sievers (ed.), John Wiley & Sons, New York, 1995, pp. 127-142.
-
Gas Chromatography – Theory and Instrumentation: Column Types, H. H. Hill, Jr. and G. Simpson, in Encyclopedia of Analytical Science, Academic Press, London, 1995, pp. 1766-1771.
-
Electrospray Ionization Ion Mobility Spectrometry, D. P. Wittmer, Y. H. Chen, B. K. Luckenbill, and H. H. Hill, Jr., Anal. Chem., 66, 2348-2355, 1994.
-
Analytical Merit of Electrospray Ion Mobility Spectrometry as a Chromatographic Detector, Y. H. Chen, H. H. Hill, Jr., and D. P. Wittmer, J. Microcol. Sep., 6, 515-524, 1994.
-
Measuring the Resolving Power of Ion Mobility Spectrometers, W. F. Siems, C. Wu, E. E. Tarver, H. H. Hill, Jr., P. R. Larsen, and D. G. McMinn, Anal. Chem., 1994, 66, 4195-4201.
-
Carbon Dioxide Supercritical Fluid Extraction of Incinerator Fly Ash with a Reactive Solvent Modifier, J. W. Hills, H. H. Hill, Jr., D. Hansen, and S. G. Metcalf, J. Chromatogr., 679, 319-328, 1994.
-
Ion Mobility Spectrometry for the Analysis of Soil-Gas Samples, T. L. Jones, K. Brown, and H. H. Hill, Jr., EPA Technology Support, 1994.
-
Fundamental Reviews of Gas Chromatography, G. A. Eiceman, H. H. Hill, Jr., and B. Davani, Anal. Chem., 66, 621R-633R, 1994.
-
Supercritical Fluid Extraction of 2,4-D from Soils Using Derivatization and Ionic Modifiers, E. A. Rochette, J. B. Harsh, and H. H. Hill, Jr., Talanta, 40(2), 147-155, 1993.
-
Carbon Dioxide Supercritical Fluid Extraction with a Reactive Solvent Modifier for the Determination of Polycyclic Aromatic Hydrocarbons, J. W. Hills and H. H. Hill, Jr., J. Chromatogr. Sci., 1, 6-12, 1993.
-
A Detection Method for Unified Chromatography: Ion Mobility Monitoring, H. H. Hill, Jr., R. H. St. Louis, M. A. Morrissey, C. B. Shumate, W. F. Siems, and D. G. McMinn, J. High Res. Chromatogr., 15, 417-422, 1992.
-
Comparison of a Pulsed Electron Capture Detector and a Fourier Transform Ion Mobility Detector After Capillary Supercritical Fluid Chromatography, E. E. Tarver and H. H. Hill, Jr., Fresenius J. Anal. Chem., 344, 453-459, 1992.
-
Fourier Transform Ion Mobility Spectrometry for Detection After SFC, H. H. Hill, Jr. and E. E. Tarver, in Hyphenated Techniques in Supercritical Fluid Chromatography and Extraction, K. Jinno (ed.), Elsevier, Amsterdam, 1992, pp. 9-24.
-
Quantification of Mammalian Lignans in Biological Fluids Using Gas Chromatography with Ion Mobility Detection, D. A. Atkinson, H. H. Hill, Jr., and T. D. Schultz, J. Chromatogr., 617, 173-179, 1993.
-
Instrumentation for Trace Organic Monitoring, R. E. Clement, K. W. M. Siu, and H. H. Hill, Jr., (eds.), Lewis Publishers, Chelsea, MI, 1992
-
Detectors in Capillary Chromatography, H. H. Hill, Jr. and D. G. McMinn, in Detectors for Capillary Chromatography, H. H. Hill, Jr. and D. G. McMinn (eds.), John Wiley & Sons, New York, 1992, pp. 1-5.
-
Gas, Supercritical Fluid, and Liquid Chromatographic Detection of Trace Organics by Ion Mobility Spectrometry, H. H. Hill, Jr. , W. F. Siems, R. L. Eatherton, R. H. St. Louis, M. A. Morrissey, C. B. Shumate, and D. G. McMinn, in Instrumentation for Trace Organic Monitoring, R. E. Clement, K. W. M. Siu, and H. H. Hill, Jr. (eds.), Lewis Publishers, Chelsea, MI, 1992, pp. 49-64.
-
Electrospray Ion Mobility Spectrometry: Its Potential as a Liquid Stream Process Sensor, C. B. Shumate and H. H. Hill, Jr., in Pollution Prevention and Process Analytical Chemistry, J. Breen and M. Dellarco (eds.), ACS Books, Washington, DC, 1992, pp. 192-205.
-
General Detection Problems in SFC, H. H. Hill, Jr. and D. A. Atkinson, in Hyphenated Techniques in Supercritical Fluid Chromatography and Extraction, K. Jinno (ed.), Elsevier, Amsterdam, 1992, pp. 1-8.
-
Analytical Supercritical Fluid Chromatography and Extraction, J. W. King, H. H. Hill, Jr., and M. L. Lee, in Physical Methods of Chemistry, B. W. Rossiter, J. F. Hamilton, and R. C. Baetzold (eds.), John Wiley & Sons, New York, 1992, pp. 1-83.
-
The Flame Ionization Detector, D. G. McMinn and H. H. Hill, Jr., in Detectors for Capillary Chromatography, H. H. Hill, Jr. and D. G. McMinn (eds.), John Wiley & Sons, New York, 1992, pp. 7-21.
-
Fundamental Reviews in Gas Chromatography, G. A. Eiceman, R. E. Clement, and H. H. Hill, Jr., Anal. Chem., 64(12), 170R-180R, 1992.
-
The Ion Mobility Detector, H. H. Hill, Jr. and D. G. McMinn, in Detectors for Capillary Chromatography, H. H. Hill, Jr. and D. G. McMinn (eds.), John Wiley & Sons, New York, 1992, pp. 297-325.
-
Apodization Functions in Fourier Transform Ion Mobility Spectrometry (FT-IMS), R. H. St. Louis, W. F. Siems, and H. H. Hill, Jr., Anal. Chem., 1992, 64, 171-177.
-
Analysis of Lipids in Aging Seed Using Capillary Supercritical Fluid Chromatography, R. M. Hannan and H. H. Hill, Jr., J. Chromatogr., 547, 393-401, 1991.
-
Differences in Lipid Profiles from Fresh and Aged Lettuce (Lactuca Sativa L.) Seed Determined by Capillary Supercritical Fluid Chromatography and GC/Mass Spectrometry, R. M. Hannan and H. H. Hill, Jr., J. Seed Technol., 15(2), 1991.
-
Simultaneous Supercritical Fluid Derivatization and Extraction, J. W. Hills, H. H. Hill, Jr., and T. Maeda, Anal. Chem., 63(19), 2152-2155, 1991.
-
Construction of a Mass Spectrometer for Sampling Ions from Diffusion Flames , C. H. Lillie, D. G. McMinn, H. Chambers, and H. H. Hill, Jr., Int. J. Mass Spec. and Ion Processes, 95, 277-287, 1990.
-
Detection Limits of an Ion Mobility Detector After Capillary Gas Chromatography, R. H. St. Louis, W. F. Siems, and H. H. Hill, Jr., J. Microcol. Sep., 2, 138-145, 1990.
-
Subcutaneous Infusions for Control of Cancer Symptoms, P. Storey, H. H. Hill, Jr., R. H. St. Louis, and E. E. Tarver, J. Pain and Symp. Manage., 5(1), 885-894, 1990.
-
Ion Mobility Detection Following Liquid Chromatographic Separation, D. G. McMinn, J. A. Kinzer, C. B. Shumate, W. F. Siems, and H. H. Hill, Jr., J. Microcol. Sep., 2, 188-192, 1990.
-
Sheathed-Flow Hydrogen Atmosphere Flame Ionization Detector for Gas Chromatography, M. M. Gallagher, D. G. McMinn, and H. H. Hill, Jr., J. Chromatogr., 518, 297-305, 1990.
-
Ion Mobility Detection of Polydimethylsilicone Oligomers Following Supercritical Fluid Chromatographic Separation, M. A. Morrissey, W. F. Siems, and H. H. Hill, Jr., J. Chromatogr., 505, 215-225, 1990.
-
Electron Capture Ion Mobility Spectrometry for the Selective Detection of Chlorinated and Brominated Species After Capillary Gas Chromatography, R. H. St. Louis and H. H. Hill, Jr., J. High Res. Chromatogr. & Chromatogr. Comm., 13, 628-632, 1990.
-
Selectivity Enhancement of a Metal-Sensitive Flame Ionization Detector for Capillary Gas Chromatography, M. M. Gallagher and H. H. Hill, Jr., J. High Res. Chromatogr., 13, 694-696, 1990.
-
Mass Spectral Identification of Response Ions in a Metal Selective Flame Ionization Detector, C. H. Lillie, D. G. McMinn, and H. H. Hill, Jr., Int. J. Mass Spec. and Ion Processes, 103, 219-230, 1990.
-
Ion Mobility Detection, H. H. Hill, Jr., in Analytical Supercritical Fluid Chromatography and Extraction, M. L. Lee and K. E. Markides (eds.), Chromatography Conferences, Inc., Provo, UT, 1990, pp. 238-245.
-
Peer Review Report of the Research Program on Hazardous Waste Combustion Measurements, V. C. Stamoudis, H. W. Edwards, H. H. Hill, Jr., and W. B. Innes, EPA Report, 1990.
-
Fundamentals of Detection After Supercritical Fluid Chromatography, H. H. Hill, Jr. and M. M. Gallagher, J. Microcol. Sep., 2, 114-119, 1990.
-
Ion Mobility Spectrometry in Analytical Chemistry, R. H. St. Louis and H. H. Hill, Jr., CRC Crit. Rev. Anal. Chem., 21(5), 321-355, 1990.
-
Fundamental Reviews in Gas Chromatography, R. E. Clement, F. I. Onuska, G. A. Eiceman, and H. H. Hill, Jr., Anal. Chem., 1990, 62, 414R-422R.
-
Qualitative and Quantitative Methods of Analysis for Gas Chromatography, R. H. St. Louis and H. H. Hill, Jr., in Gas Chromatography: Biochemical, Biomedical, and Clinical Applications, R. Clement (ed.), John Wiley & Sons, New York, 1990, pp. 109-127.
-
Ion Mobility Spectrometry, H. H. Hill, Jr., W. F. Siems, R. H. St. Louis, and D. G. McMinn, Anal. Chem., 62(23), 1201A-1209A, 1990.
-
Coronaspray Nebulization and Ionization of Liquid Samples for Ion Mobility Spectrometry, C. B. Shumate and H. H. Hill, Jr., Anal. Chem., 61, 601-606, 1989.
-
Selective Detection of Underivatized 2,4-Dichlorophenoxyacetic Acid in Soil by Supercritical Fluid Chromatography with Ion Mobility Detection, M. A. Morrissey and H. H. Hill, Jr., J. Chromatogr. Sci., 27, 529-533, 1989.
-
Symposium/Workshop on Supercritical Fluid Chromatography, H. H. Hill, Jr., J. Microcol. Sep., 1(5), 260-261, 1989.
-
Preliminary Investigation of Ion Mobility Spectrometry After Capillary Electrophoretic Introduction, R. W. Hallen, C. B. Shumate, W. F. Siems, T. Tsuda, H. H. Hill, Jr., J. Chromatogr., 480, 233-245, 1989.
-
Evaluation of Direct Axial Sample Introduction for Ion Mobility Detection After Capillary Gas Chromatography, R. H. St. Louis, W. F. Siems, H. H. Hill, Jr., J. Chromatogr., 479, 221-231, 1989.
-
Ambient Pressure Ionization Methods for Environmental Analysis, H. H. Hill, Jr., Proc. Env. Res. Technol. Trans. Conf., 1, 32-35, 1989.
-
Detection Systems for Capillary Supercritical Fluid Chromatography, H. H. Hill, Jr. and C. B. Shumate, in MICRO-HPLC, F. J. Yang (ed.), Marcel Dekker, New York, 1989, pp. 267-306.
-
Metal Selective Flame Ionization Detection After Supercritical Fluid Chromatography, M. A. Morrissey and H. H. Hill, Jr., J. High Res. Chromatogr. & Chromatogr. Comm., 11, 375-379, 1988.
-
Comparison of Ion Mobility Constants of Selected Drugs After Capillary Gas Chromatography and Capillary Supercritical Fluid Chromatography, R. L. Eatherton, M. A. Morrissey, and H. H. Hill, Jr., Anal. Chem., 60, 2240-2243, 1988.
-
Ion Mobility Detection After Capillary Gas Chromatography, R. H. St. Louis, W. F. Siems, and H. H. Hill, Jr., LC-GC, 9, 810-814, 1988.
-
Ion Mobility Spectrometry After Chromatography: Accomplishments, Goals, Challenges, H. H. Hill, Jr. and R. L. Eatherton. J. Res. Nat. Bur. Stand., 93(3), 1988, 425-426, 1988.
-
Ion Mobility Spectrometry as a Detection Method for Supercritical Fluid Chromatography, H. H. Hill, Jr. and M. A. Morrissey, in Modern Supercritical Fluid Chromatography, C. W. White (ed.), Huethig Publishing Ltd., New York, 1988, pp. 95-113.
-
Fundamental Reviews of Gas Chromatography, R. E. Clement, F. I. Onuska, G. A. Eiceman, and H. H. Hill, Jr., Anal. Chem., 60, 279R-294R, 1988.
-
Ion Mobility Spectrometry After Supercritical Fluid Chromatography, S. Rokushika, H. Hatano, and H. H. Hill, Jr., Anal. Chem., 59, 8-12, 1987.
-
Simultaneous Ultrasonic Extraction and Silylation (SUES) for the Determination of Organic Acids, Alcohols, and Phenols from Airborne Particulate Matter, R. Gholson, R. H. St. Louis, and H. H. Hill, Jr., Assoc. Off. Anal. Chem., 70(50), 897-902, 1987.
-
Determination of Silicon Number in Silylated Organic Compounds Using the Hydrogen Atmosphere Flame Ionization Detector, R. Gholson, R. H. St. Louis, and H. H. Hill, Jr., J. Chromatogr., 408, 329-334, 1987.
-
Resolution Measurement for Ion Mobility Spectrometry, S. Rokushika, H. Hatano, M. A. Baim, and H. H. Hill, Jr., Anal. Chem., 57, 1902-1907, 1985.
-
Fourier Transform Ion Mobility Spectrometry of Barbiturates After Capillary Gas Chromatography, R. L. Eatherton, W. F. Siems, and H. H. Hill, Jr., J. High Res. Chromatogr. & Chromatogr. Comm., 9, 44-48, 1986.*
-
Ion Mobility Detection After Supercritical Fluid Chromatography, R. L. Eatherton, M. A. Morrissey, W. F. Siems, and H. H. Hill, Jr., J. High Res. Chromatogr. & Chromatogr. Comm., 9, 154-160, 1986.*
-
Prediction of Ion Separation from Literature Data for the Ion Mobility Detector, S. Rokushika, H. Hatano, M. A. Baim, and H. H. Hill, Jr., J. Chromatogr., 356, 393-399, 1986.
-
Table of Reduced Mobility Values from Ambient Pressure Ion Mobility Spectrometry, C. Shumate, R. H. St. Louis, and H. H. Hill, Jr., J. Chromatogr., 373, 141-173, 1986.
-
Chemical Analysis by Time Dispersive Ion Spectrometry, F. J. Knorr, R. L. Eatherton, W. F. Siems, H. H. Hill, Jr., U. S. Patent, No. 4,633,083, Dec. 30, 1986.
-
Fundamental Reviews in Gas Chromatography, R. E. Clement, F. I. Onuska, F. I . Yang , G. A. Eiceman, and H. H. Hill, Jr., Anal. Chem., 58, 321R-335R, 1986.
-
Detection of Organotins After Gas Chromatography by Flame Ionization-Quenching, D. R. Hanson, C. H. Lillie, and H. H. Hill, Jr., J. Chromatogr. Sci., 23, 208-213, 1985.
-
Fourier Transform Ion Mobility Spectrometry, F. J. Knorr, R. L. Eatherton, W. F. Siems, and H. H. Hill, Jr., Anal. Chem., 57, 402-406, 1985.
-
Ion Mobility Spectrometry in Carbon Dioxide, S. Rokushika, H Hatano, and H. H. Hill, Jr., Anal. Chem., 58, 361-365, 1986.
-
Bridging the Gap with Supercritical Fluid Chromatography, H. H. Hill, Jr. and M. Morrissey, Chromatography Review, 12(2), 1985.
-
Plasma Chromatography as a Gas Chromatographic Detection Method, H. H. Hill, Jr. and M. A. Baim, in Plasma Chromatography, T. W. Carr (ed.), Plenum Publishing, 1984, pp. 143-176, 1984.
-
Multi-Parameter Optimization of a Hydrogen Atmosphere Flame Ionization Detector, D. G. McMinn, R. L. Eatherton, and H. H. Hill, Jr., Anal. Chem., 56, 1293-1298, 1984.
-
Effects of Contamination on Ion Mobility Detection After Gas Chromatography, M. A. Baim and H. H. Hill, Jr., J. Chromatogr., 299, 309-319, 1984.
-
Ionization Quenching of a Hydrogen Atmosphere Flame as a Detection Method for Gas Chromatography, D. R. Hansen and H. H. Hill, Jr., J. Chromatogr., 303, 331-340, 1984.
-
Book review of Gas Chromatography of Organometallic Compounds by T. R. Crompton, H. H. Hill, Jr., Trends in Analytical Chemistry, 3(6), XII, 1984.
-
Halogenated Compound Response in an Oxygen Doped Ion Mobility Detector for Gas Chromatography, M. A. Baim and H. H. Hill, Jr., J. High. Res. Chromatogr. & Chromatogr. Comm., 6, 4-10, 1983.
-
Phosphorus Response in a Hydrogen Atmosphere Flame Ionization Detector for Gas Chromatography, M. A. Osman and H. H. Hill, Jr., J. Chromatogr., 264, 149-153, 1983.
-
Ion Mobility Detector for Gas Chromatography with a Direct Photoionization Source, M. A. Baim, R. L. Eatherton, and H. H. Hill, Jr., Anal. Chem., 55, 1761-1766, 1983.
-
Photoionization/Flame Ionization Detection of Atmospheric Hydrocarbons after Capillary Gas Chromatography, W. Nutmagul, D. R. Cronn, and H. H. Hill, Jr., Anal. Chem., 55, 2160-2164, 1983.
-
Determination of 2,4-Dichlorophenoxyacetic Acid in Soils by Capillary Gas Chromatography with Ion Mobility Detection, M. A. Baim and H. H. Hill, Jr., J. Chromatogr., 279, 631-642, 1983.
-
Tunable Selective Detection of Capillary Gas Chromatography by Ion Mobility Monitoring, M. A. Baim and H. H. Hill, Jr., Anal. Chem., 54, 38-43, 1982.
-
A Microprocessor Controlled Ion Mobility Spectrometer for Selective and Nonselective Detection Following Gas Chromatography, M. A. Baim, F. J. Schuetze, J. M. Frame, and H. H. Hill, Jr., Amer. Lab., 14(2), 59-70, 1982.
-
Ambient Pressure Ionization Detectors for Gas Chromatography, Part I: Flame and Photoionization Detectors, H. H. Hill, Jr. and M. A. Baim, Trends in Anal. Chem., 1(9), 206-210, 1982.
-
Ambient Pressure Ionization Detectors for Gas Chromatography, Part II: Radioactive Source Ionization Detectors, H. H. Hill, Jr. and M. A. Baim, Trends in Anal. Chem., 1(10), 232-236, 1982.
-
Negative Response Mode of a Silicon-Selective Hydrogen-Atmosphere Flame Ionization Detector for Gas Chromatography, M. A. Osman and H. H. Hill, Jr., Anal. Chem., 54, 1425-1428, 1982.
-
Silicon-Selective Detection after Gas Chromatography for the Determination of Silylated Salicylic Acid in Urine, M. A. Osman and H. H. Hill, Jr., J. Chromatogr., Biomedical Applications, 232, 430-434, 1982.
-
Temperature Monitor with Dual-Channel Platinum Resistance Elements, M. A. Baim, F. J. Schuetze, J. M. Frame, and H. H. Hill, Jr., Anal. Chem., 54, 1908-1909, 1982.
-
Analytical Methodology for the Identification and Quantification of Vapor Phase Organic Pollutants, H. H. Westberg, M. W. Holdren, and H. H. Hill, Jr., NTIS Report, PB82-255753, 1982.
-
Book Review of Organic Trace Analysis by Liquid Chromatography by J. F. Lawrence, H. H. Hill, Jr., J. Am. Chem. Soc., 105(15), 5171, 1983.
-
Comparison of Metal-Sensitive Flame Ionization and Carbon-Sensitive Flame Ionization Detectors for the Gas Chromatographic Determination of Organotins, D. R. Hansen, T. J. Gilfoil, and H. H. Hill, Jr., Anal. Chem., 53, 857-861, 1981.
-
Iodine-Doped Selective Ionization Detector for Gas Chromatography, T. J. Gilfoil, A. Gholson, and H. H. Hill, Jr., J. Chromatogr., 210, 409-418, 1981.
-
Response Enhancement by Metal Doping of a Silicon-Selective Flame Ionization Detector for Gas Chromatography, M. Osman and H. H. Hill, Jr., J. Chromatogr., 213, 397-412, 1981.
-
Trace Level Analysis of Ambient Organic Species Using Solid Adsorbent and Derivatization Technology, H. H. Westberg, A. R. Gholson, and H. H. Hill, Jr., Proc. Annu. Meet. – Air Pollut. Control Assoc., 74th(3), paper 81-47.2, 1981.
-
Survey of Selected Hydrides as Doping Agents for a Hydrogen-Atmosphere Flame Ionization Detector, M. D. Dupuis and H. H. Hill, Jr., J. Chromatogr., 195, 211-220, 1980.
-
Analysis of Hydrocarbons in a Hydrogen Atmosphere by Gas Chromatography with Flame Ionization, J. H. Wagner, C. H. Lillie, M. D. Dupuis, and H. H. Hill, Jr., Anal. Chem., 52, 1614-1617, 1980.
-
Analysis of Gasoline for Antiknock Agents with a Hydrogen-Atmosphere Flame Ionization Detector, M. D. Dupuis and H. H. Hill, Jr., Anal. Chem., 51(2), 292-295, 1979.
-
Gas Chromatography of Drugs on Carbowax 20 M Deactivated Support, C. R. Fontan and H. H. Hill, Jr., J. Chromatogr., 170(1), 249-253, 1979.
-
Silicon Selective Non-Doped Hydrogen-Atmosphere Flame Ionization Detector for Gas Chromatography, M. Osman, H. H. Hill, Jr., M. Holdren, and H. Westberg, Anal. Chem., 51, 1286-1292, 1979.
-
Parameter Study of a Hydrogen Atmosphere Flame Ionization Detector, J. E. Roberts and H. H. Hill, Jr., J. Chromatogr., 176, 1-9, 1979.
-
Analytical Techniques to Establish the Identity and Concentration of Vapor Phase Organic Compounds, M. Holdren, S. Humrickhouse, S. Truitt, H. Westberg, and H. H. Hill, Jr., Proc. Annu. Meet. – Air Pollut. Control Assoc., 72nd(4), paper 79-52.2, 1979.
-
Vapor Phase Silylation of Alcohols for Air Analysis, M. Osman, H. H. Hill, Jr., M. Holdren, and H Westberg, J. Chromatogr., 186, 273-284, 1979.
-
Air Pollution Analysis from Exposed Surfaces by ISS/SIMS, F. W. Karasek, A. Maican,